Publicación:
Measurement, Validation and Uncertainty of an Experimental Procedure to Characterize the Size-of-Source Effect of Radiation Thermometers, in the Framework of an Industrial Calibration Laboratory

dc.contributor.authorDe Lucas Veguillas, Javieres
dc.contributor.funderInstituto Nacional de Técnica Aeroespacial (INTA)es
dc.date.accessioned2024-02-26T12:45:57Z
dc.date.available2024-02-26T12:45:57Z
dc.date.issued2022-10-28
dc.descriptionJavier de Lucas Veguillas [0000-0001-9030-6721] Data access requests from academic investigators can be directed to the corresponding author.es
dc.description.abstractAn experimental procedure for characterizing the size-of-source effect (SSE) is proposed. Such an effect is the cause of one of the main influence variables generating uncertainty in the measurement, both in calibration and use, of direct reading radiation thermometers (RT). The procedure and uncertainty calculation described in the paper are aligned in terms of metrological traceability, with the requirements generally imposed to ensure the accuracy of measurements in industry and science. Results of application and validation of this particular procedure with equipment, including black body (BB) sources normally used in radiation thermometry calibration laboratories in the industrial field, are shown.es
dc.description.peerreviewedPeerreviewes
dc.description.sponsorshipThis research received no external funding.es
dc.identifier.citationSensors 22(21): 8284(2022)es
dc.identifier.doi10.3390/s22218284
dc.identifier.e-issn1424-8220
dc.identifier.otherhttps://www.mdpi.com/1424-8220/22/21/8284es
dc.identifier.urihttp://hdl.handle.net/20.500.12666/943
dc.language.isoenges
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)es
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationales
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.license© 2022 by the author. Licensee MDPI, Basel, Switzerland.es
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.subjectRadiation thermometeres
dc.subjectThermometryes
dc.subjectIndustrial calibrationes
dc.subjectMetrologyes
dc.subjectTraceabilityes
dc.subjectBlackbodyes
dc.subjectEmissivityes
dc.titleMeasurement, Validation and Uncertainty of an Experimental Procedure to Characterize the Size-of-Source Effect of Radiation Thermometers, in the Framework of an Industrial Calibration Laboratoryes
dc.typeinfo:eu-repo/semantics/articlees
dc.type.coarhttp://purl.org/coar/resource_type/c_6501es
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Measurement, validation and uncertainty of an experimental procedure to Characterize the size-of-source effect of radiation thermometers, in the framework of an industrial calibration laboratory.pdf
Tamaño:
3.77 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
4.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción: