Publicación: Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor
dc.contributor.author | González Guerrero, M. | es |
dc.contributor.author | Jiménez, J. J. | es |
dc.contributor.author | Hernando, Carlos | es |
dc.contributor.author | Álvarez, Maite | es |
dc.contributor.author | Guerrero, H. | es |
dc.contributor.funder | Instituto Nacional de Técnica Aeroespacial (INTA) | es |
dc.date.accessioned | 2023-03-07T10:59:06Z | |
dc.date.available | 2023-03-07T10:59:06Z | |
dc.date.issued | 2013-05-14 | |
dc.description.abstract | A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite. | es |
dc.description.peerreviewed | Peerreview | es |
dc.description.sponsorship | The authors would like to thank the work group at the gamma-facility of the University of Santiago de Compostela, especially the Dr. D. M. González, for their very professional support during the irradiation tests. The authors would also like to thank B. Martín for his careful preparation of the electronic boards. | es |
dc.identifier.citation | IEEE Transactions on Nuclear Science 60(4): 2461-2468(2013) | es |
dc.identifier.doi | 10.1109/TNS.2013.2257848 | |
dc.identifier.issn | 0018-2468 | |
dc.identifier.issn | 1558-1578 | |
dc.identifier.other | https://ieeexplore.ieee.org/document/6516099 | es |
dc.identifier.uri | http://hdl.handle.net/20.500.12666/852 | |
dc.language.iso | eng | es |
dc.publisher | Institute of Electrical and Electronics Engineers | es |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.license | Copyright © 2013, IEEE | es |
dc.subject | Data analysis | es |
dc.subject | Dosimetry | es |
dc.subject | Ionizing dose | es |
dc.subject | Radiation effects in devices | es |
dc.subject | Space radiation environment | es |
dc.subject | Total dose effects | es |
dc.title | Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor | es |
dc.type | info:eu-repo/semantics/article | es |
dc.type.coar | http://purl.org/coar/resource_type/c_6501 | es |
dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | es |
dspace.entity.type | Publication |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- acceso-restringido.pdf
- Tamaño:
- 221.73 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 4.82 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: