Publicación:
Lock-in amplifiers for AMR sensors

dc.contributor.authorDíaz Michelena, M.
dc.contributor.authorCobos, P.
dc.contributor.authorAroca, C.
dc.date.accessioned2022-02-11T08:54:39Z
dc.date.available2022-02-11T08:54:39Z
dc.date.issued2015-02-01
dc.description.abstractAnisotropic magnetoresistive (AMR) magnetic sensors are often chosen as the magnetic transducer for magnetic field sensing in applications with low to moderate magnetic field resolution because of the relative low mass of the sensor and their ease of use. They measure magnetic fields in the order of the Earth magnetic field (with typical sensitivities of 1‰/G or 10−2‰/μT), have typical minimum detectable fields in order of nT and even 0.1 nT but they are seriously limited by the thermal drifts due to the variation of the resistivity with temperature (∼2.5‰/°C) and the variation of the magnetoresistive effect with temperature (which affects both the sensitivity of the sensors: ∼2.7‰/°C, and the offset: ±0.5‰/°C). Therefore, for lower magnetic fields, fluxgate vector sensors are generally preferred. In the present work these limitations of AMR sensors are outlined and studied. Three methods based on lock-in amplifiers are proposed as low noise techniques. Their performance has been simulated, experimentally tested and comparatively discussed. The developed model has been also used to derive a technique for temperature compensation of AMR response. The final goal to implement these techniques in a space qualified applied specific integrated circuit (ASIC) for Mars in situ exploration with compact miniaturized magnetometers.es
dc.description.peerreviewedPeerreviewes
dc.identifier.citationSensors and Actuators A: Physical 222: 149-159(2015)es
dc.identifier.doi10.1016/j.sna.2014.11.005
dc.identifier.issn0924-4247
dc.identifier.otherhttps://www.sciencedirect.com/science/article/abs/pii/S0924424714004804
dc.identifier.urihttp://hdl.handle.net/20.500.12666/516
dc.language.isoenges
dc.publisherElsevieres
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess
dc.rights.licenseCopyright © 2014 Elsevier B.V. All rights reserved.
dc.subjectMagnetic Sensorses
dc.subjectAMR magnetometerses
dc.subjectFluxgate sensorses
dc.subjectLow noise and temperature compensationes
dc.titleLock-in amplifiers for AMR sensorses
dc.typeinfo:eu-repo/semantics/articlees
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
acceso-restringido.pdf
Tamaño:
221.73 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
4.82 KB
Formato:
Item-specific license agreed upon to submission
Descripción: