Publicación:
Gamma Irradiation of Magnetoresistive Sensors for Planetary Exploration

Fecha

2012-04-02

Título de la revista

ISSN de la revista

Título del volumen

Editor

Multidisciplinary Digital Publishing Institute (MDPI)

Proyectos de investigación

Unidades organizativas

Número de la revista

Resumen

A limited number of Anisotropic Magnetoresistive (AMR) commercial-off-the-shelf (COTS) magnetic sensors of the HMC series by Honeywell, with and without integrated front-end electronics, were irradiated with gamma rays up to a total irradiation dose of 200 krad (Si), following the ESCC Basic Specification No. 22900. Due to the magnetic cleanliness required for these tests a special set-up was designed and successfully employed. Several parameters of the sensors were monitored during testing and the results are reported in this paper. The authors conclude that AMR sensors without front-end electronics seem to be robust against radiation doses of up to 200 krad (Si) with a dose rate of 5 krad (Si)/hour and up to a resolution of tens of nT, but sensors with an integrated front-end seem to be more vulnerable to radiation.

Descripción

This is an open access article distributed under the Creative Commons Attribution License

Palabras clave

Magnetic devices, Radiation effects in devices, Gamma ray effects, Space applications, Space radiation effects

Citación

Sensors 12(4): 4447-4465(2012)